INSTALLATION INSTRUCTIONS
1. All electrical connections must be in accordance with local
codes, ordinances, or Canadian Electrical Code. If you are
unfamiliar with methods of installing electrical wiring, secure
the service of a qualified electrician.
2. To avoid motor bearing damage and/or noisy and unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
This unit mounts between walls 4½" to 9½" thick. Outside housing
flange is fastened to casing strips (1 x 2's). See Fig. 1. If sheathing
behind siding is not wood, provide extra supports between walls
(Nailed or screwed to siding).
1. Remove motor assembly by loosening mounting screws, rotat-
ing assembly and lifting motor assembly out of inner housing
(Figure 2).
2. Use care when handling motor bracket assembly to prevent
damage to blade. Do not set down assembly with weight of
motor resting on the blade.
3. Pull inner housing out of outer housing.
4. Remove wiring knockout from bottom of wiring box (provided
in plastic parts bag) (Figure 2).
Remove bottom knockout ONLY!
1. Choose fan location from inside room. Make sure that wall stud
does not run through opening. Lay out hole on wall (Figure
3).
2. Transfer center of hole to outside wall.
FIG. 3

TYPICAL INSTALLATION

PREPARE FAN
NOTE
FIG. 2
3. Use care when handling motor bracket assembly to prevent
damage to blade. Do not set down assembly with weight of
motor resting on the blade.
4. Disconnect electrical power supply before installing or servic-
ing fan.
fIG. 1
FIG. 1
FIG. 2
INSTALL FAN
3. Cut out hole on side wall.
4. Lay out 14½" square around center location transferred from
inside room (Figure 4).
FIG. 4

Advertisement

loading

Summary of Contents for Broan 508N

  • Page 1: Typical Installation

    Models 508N / 509N INSTALLATION INSTRUCTIONS 1. All electrical connections must be in accordance with local 3. Use care when handling motor bracket assembly to prevent codes, ordinances, or Canadian Electrical Code. If you are damage to blade. Do not set down assembly with weight of unfamiliar with methods of installing electrical wiring, secure motor resting on the blade.
  • Page 2 INSTALL FAN (Cont’d) 5. Cut square hole in SIDING ONLY! DO NOT CUT SHEATHING FIG. 9 (Figure 5)! Nail down all siding ends. FIG. 5 12. Attach wiring to wiring box with proper connector for type of 6. Cut round hole for fan housing in sheathing (Figure 6). wire being used.
  • Page 3 Modèles 508N / 509N DIRECTIVES POUR L’INSTALLATION 1. L’installation électrique doit être conforme aux ordonances ou 3. Prenez soin en manipulant le support de moteur, pour codes locaux ou fédéral. La personne qui n’est pas experte en empêcher des dommages à la lame. N’établissez pas le électericité...
  • Page 4 INSTALLATION DU VENTILATEUR (Suite) 5. Découper un trou en forme de carré SEULEMENT DANS LE FIG. 9 PAREMENT (Fig. 5). Clouer tous les bouts de parements. FIG. 5 12. Brancher les câbles à la boîte de câblae avec un connecteur 6.