Cabinet requirements
Electrical requiements
6
All manuals and user guides at all-guides.com
The distance from the top of the cooktop to the bottom of cabinets above it must be
A = 30" (762 mm) min. This distance can be reduced to A = 24" (610 mm) when the
bottom of the wood or metal cabinet is protected by not less than 1/4" (6.35mm)
flame retardant millboard, covered by no. 28 MSG sheet steel, 0.015" (0.4 mm)
thick stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) thick copper.
Verify that cabinets above the cooktop are a maximum of B=13" (330mm) deep.
You can find the identification plate with the electrical specifications on the
underside of the appliance. See Product Data Plate" under Service" for data plate
location.
The junction box must be located within 3 feet of the cooktop connection. It should
be easily accessible for service purposes.
(Conduit approx. 3 feet)
All with 1m flexible conduit (included)
12" Approximate
J" Box

Power Supply

Models NIT8053UC
40 Amp circuit breaker
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz