81040_5.book Page 28 Monday, February 20, 2006 2:39 PM
28
• Select the log distance units
• Either calibrate the speed reading to Speed Over Ground (SOG) or manually
apply a calibration factor, to obtain correct speed through the water.
• Select temperature units.
• Calibrate for correct temperature readings.
• Set timer alarm buzzer on or off.
Separate routines are provided for the User calibration of the depth and speed
functions. To carry out either of these routines:
1. Power up the ST60 Tridata instrument.
To start User calibration
depth
for approximately 2 seconds
Starting User calibration
2. Press the depth and speed keys for approximately 2 seconds so that the
User calibration entry screen is displayed.
3. Carry out the User calibration procedures for
Depth
To calibrate the depth functions:
1. With the User calibration entry screen displayed, press the depth key.
2. Referring to the
tion procedure. Use the depth key to cycle from screen to screen and the
trip
ST60 Tridata Instrument Owner's Manual
hold down
and
speed
User calibration
entry screen
press either
depth
or
speed
User calibration - depth
and reset keys to set the required values at each screen.
User calibration - depth
see
illustration
User calibration - speed
see
illustration
Depth
Speed
and
illustration, carry out the calibra-
D4416-1
.