Installation - Kohler SAN RAPHAEL K-3722T-C Installation Instructions Manual

Class five vitreous china skirted trapway one-piece toilet

Advertisement

Finished Wall

INSTALLATION

TO REMOVE EXISTING TOILET
Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.
Remove the old gasket from the floor
and the closet flange with a putty knife.
Remove the old T-bolts and discard
them.
NOTICE:
if the new toilet is not
installed immediately, temporarily stuff
a rag into the closet flange.
NOTICE: Do not use white cement or high lime content
cements to install this toilet. The expansion of cement due to
a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused by
installation with the use of cement.
TO INSTALL SUPPLY
SHUT-OFF VALVE
Install the supply shut-off valve so it is
67mm (2-5/8") above the finished floor
line, and 194mm (7-5/8") to the left of
the closet flange centerline.
The centerline of the supply shut-off
valve outlet should extend 67mm
(2-5/8") from the finished wall. Install
the supply shut-off valve with the outlet
vertical.
1128502-T01-E
743
380
400
C
L
OF OUTLET
Kohler reserves the right to change marked dimensions without prior notice.
67
305/400
K-4027T/K-4027T-C
519
610
67
194
Fig.#1
1
Fig.#2
Closet Flange
2
Supply Shut-Off Valve
194
Closet Flange
Centerline
Fig.#3
3
-3-
FRONT OF BOWL
(
)
mm
316
379
T
67
194
mm
67mm;

Advertisement

loading

This manual is also suitable for:

San raphael k-3722tSan raphael k-3722t-pgSan raphael k-3722t-bgSan raphael k-4027tSan raphael k-4027t-c