Rack-mount Model (Model R620-LR, R620-MR)

Do not install the server on a nonconforming rack.
Install the server on a 19-inch rack conforming to the EIA standard. Do not use the server without a
rack or install it on a nonconforming rack. The server may not function properly, and there is a risk of
damage to physical assets or injuries. For suitable racks, contact your sales agent.
Do not use the server in an unsuitable place.
Do not install a server rack in an unsuitable environment.
Other systems also may be affected, and the rack may fall over to cause a fire or injuries. For details
about installation environment and quake-resistant engineering, see the attached manual or contact
your sales agent.
Be careful not to hurt your fingers.
Exercise great care not to hurt your fingers on the rail when you mount/dismount the server into/from
the rack.
Carry or install the server by more than 3 people.
To avoid a risk of injuries, users should not attempt to carry or install the server into a rack.
Installation should be performed by trained maintenance personnel.
Do not install the server in such a manner that its weight is imposed on a single place.
To distribute the weight, use stabilizers or attach two or more racks. Unstable rack may fall down to
cause injuries.
Do not assemble parts alone.
It takes at least two people to mount doors and trays to a rack. If you handle them alone, you may
drop some parts to cause a breakage or injuries.
Do not pull a device out of the rack if the rack is unstable.
Before pulling out a device, make sure that the rack is fixed (by stabilizers or quake-resistant
engineering).
Do not leave more than one device pulled out from the rack.
If you pull out more than one device, the rack may fall down. You can only pull out one device at a
time.
Do not install excessive wiring.
To prevent burns, fires, and damage to the server, make sure that the rated load of the power branch
circuit is not exceeded. For more information on installation and wiring of power-related facilities,
contact your electrician or local power company.
Do not pull out a device during operation.
Do not pull out or remove a device while it is running. There is a risk of malfunction and a device may
be detached from a rack to cause injuries.
NovaScale R620-LR / R620-MR Setup Guide
WARNING
CAUTION
1-10