Thermo Pride CDX1-100N Installation And Operation Manual page 49

Two stage condensing gas furnace
Table of Contents

Advertisement

All installations and services must be performed by qualified service personnel.
THE SYSTEM IS STARTED BY SETTING THE THERMOSTAT TO CALL FOR
HEAT. THE FOLLOWING SHOULD HELP ESTABLISH THE TYPE OF
MALFUNCTION OR DEVIATION FROM THE NORMAL OPERATION.
NOTE: IF LED LIGHT IS FLASHING, REFER TO PAGE 34 FOR A QUICK TROUBLESHOOTING GUIDE.
TO USE THIS DIAGRAM, YOU JUST NEED TO FOLLOW THE INSTRUCTIONS IN THE BOXES.
(MAKE CERTAIN ROOM TEMPERATURE IS BELOW THERMOSTAT SETTING)
IS THE INDUCER
BLOWER OPERATING?
YES
TROUBLESHOOTING GUIDE
SET THERMOSTAT TO CALL FOR HEAT
IS THERE 120 VOLTS
ACROSS "L1" AND
NO
"NEUTRAL" AT THE
50V61-143 CONTROL
IS THERE 24 VOLTS
ACROSS "TH" & "TR"
AT THE INTEGRATED
CONTROL MODEL
50V61-143?
IS THERE 24V
ACROSS R AND B/C
IS THERE 24 VOLTS
ACROSS "R" AND "W1"?
IS THERE LINE VOLTAGE
ACROSS INDUCER POWER
TERMINALS "IND HI" TO
"IND N" OR "IND LO" TO
"IND N" AT THE 50V61-143
CONTROL?
CHECK WIRING TO INDUCER
AND IF OK, REPLACE
INDUCER ASSEMBLY.
NO
MODULE?
YES
NO
YES
NO
YES
YES
NO
NO
YES
43
CHECK INPUT POWER,
DOOR INTERLOCK,
SERVICE SWITCH
AND FUSES
CHECK 115 VOLT
CONNECTIONS. IF OK,
REPLACE TRANSFORMER
CHECK FUSE ON
W/R 50V61-143
CHECK WIRING TO
THERMOSTAT. IF OK,
REPLACE THERMOSTAT.
REPLACE THE
50V61-143 CONTROL.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdx1-125nChx1-75nCdx1-75nChx1-100nChx1-125n

Table of Contents