Peripheral Architecture; Clock Control; Ddr2 Memory Controller Clock Block Diagram - Texas Instruments TMS320DM643 User Manual

Texas instruments ddr2 memory controller user's guide
Table of Contents

Advertisement

www.ti.com
2

Peripheral Architecture

This section describes the architecture of the DDR2 memory controller as well as how it is structured and
how it works within the context of the system-on-a-chip. The DDR2 memory controller can gluelessly
interface to most standard DDR2 SDRAM devices and supports such features as self-refresh mode and
prioritized refresh. In addition, it provides flexibility through programmable parameters such as the refresh
rate, CAS latency, and many SDRAM timing parameters. The following sections include details on how to
interface and properly configure the DDR2 memory controller to perform read and write operations to
externally-connected DDR2 SDRAM devices. Also,
the DDR2 memory controller to a common DDR2 SDRAM device.
2.1

Clock Control

The DDR2 memory controller receives two input clocks from internal clock sources, SYSCLK2 and
PLL2_SYSCLK1
(Figure
should be configured to clock at the frequency of the desired data rate, or stated similarly, it should
operate at twice the frequency of the desired DDR2 memory clock. DDR_CLK and DDR_CLK are the two
output clocks of the DDR2 memory controller providing the interface clock to the DDR2 SDRAM memory.
These two clocks operate at a frequency of PLL2_SYSCLK1/2.
2.1.1
Clock Source
SYSCLK2 and PLL2_SYSCLK1 are sourced from two independent PLLs
from PLL controller 1 (PLLC1) and PLL2_SYSCLK1 is sourced from PLL controller 2 (PLLC2).
SYSCLK2 is clocked at a fixed divider ratio of PLL1. This divider is fixed at 3, meaning SYSCLK2 is
clocked at a frequency of PLL1/3. Once inside the DDR2 memory controller, this signal is called VCLK.
PLLC2 has a programmable divider that is used to divide-down the output clock of PLL2. This divider
should be configured such that PLLC2 supplies the PLL2_SYSCLK1 at the desired frequency. For
example, if a 150-MHZ DDR2 interface clock (DDR_CLK) is desired, then PLLC2 must be configured to
generate a 300-MHZ clock on PLL2_SYSCLK1. Once inside the DDR2 memory controller,
PLL2_SYSCLK1 is called X2_CLK.
SPRU986B – November 2007
Submit Documentation Feedback
2). SYSCLK2 is a divided-down version of the DSP clock. PLL2_SYSCLK1
Figure 2. DDR2 Memory Controller Clock Block Diagram
DDR_CLK
DDR2
memory
controller
VCLK
SYSCLK2
/3
PLLC1
Section 3
provides a detailed example of interfacing
(Figure
DDR_CLK
X2_CLK
PLL2_SYSCLK1
/2
PLLC2
Peripheral Architecture
2). SYSCLK2 is sourced
DDR2 Memory Controller
9