Below is the procedures for this mode.
Step 1: Enter into Doctor mode (For more information refer to section 8.2 on key operation to enter into this mode).
Step 2: When [
], [1] & [4] are pressed at the doctor mode, the following shall be displayed for 3s. The result shall correspond
to the condition met as shown in the table below:
8.3.

Error Code Table 1

8.3.1.
Mechanism Error Code Table
Self-Diagnosis Function provides information on any problems occuring for the unit and its respective components by displaying
error codes. These error code such as U**, H** and F** are stored in memory and held unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
Error Code
Diagnosis Contents Description of error
F15
CD REST SW
abnormal
F26
Communication
between CD servo
LSI and micro-p
abnormal.
F76
Abnormality in the
output voltage of
stabilized power
supply.
CD
traverse
position
initial setting operation
failsafe
counter
(1000ms)
waiting
for
REST SW to turn on.
Error no. shall be clear
by force or during cold
start.
CD
function
DTMS
command, after system
setting, if SENSE = "L"
cannot
be
detected.
Memory
shall
contain
F26code.
After
power
on, CD function shall
continue, error display
shall be "NO DISC".
Error no. shall be clear
by force or cold start.
In
normal
operation
when
"DCDET"
is
detected "L" (IOIO) for
two consecutive times,
this error code will be
displayed for 2s & after
PCONT will be turned to
"L" (Low).
16
Automatic FL Display
Remarks
For CD unit.(For traverse).
Press [
For CD unit.(For traverse).
Press [
Press [
] on main unit for next error.
] on main unit for next error.
] on main unit for next error.