Download Print this page

Impedance Selection; Logic Connections; Audio Connections; Unbalanced High-Impedance Operation - Shure 522 User Manual

Voice communication microphone

Advertisement

Impedance Selection

Use the switch located under the microphone base, near the cable entry, to select high (HI) or low (LO) impedance.
Use the low-impedance position for long cable lengths under conditions of severe hum disturbance. Use Shure Model A95
Series Line Matching Transformers when using a low-impedance microphone line with a high-impedance amplifier input.

Logic Connections

The RED and BLACK leads may be used to control an external relay or switching circuit.

Audio Connections

Unbalanced high-impedance operation:

Set the impedance switch to the HI position (as shipped). Connect the GREEN cable lead and the shield to the amplifier chas­
sis ground. The WHITE cable lead is the "hot" conductor.

Balanced-line low-impedance operation:

Set the impedance switch to the LO position. Connect the shield to the amplifier chassis ground. The WHITE and GREEN ca­
ble leads are the "hot" conductors.
Cable-to-Connector Wiring
Input Type
Wire Color
White
Unbalanced
Green
Shield
White
Balanced
Green
Shield
Function
XLR Connector
Audio
Pin 2
Audio Ground
Pin 3
Chassis Ground
Pin 1
Audio +
Pin 2
Audio -
Pin 3
Chassis Ground
Pin 1
Shure Incorporated
1/4 in. Phone Plug
Tip
Sleeve
Sleeve
Tip
Ring
Sleeve