Installation Guide
Test
IEC 61000-4-17
IEC 61000-4-29
IEC 60255-5
a
Siemens-specified severity levels
EMC Immunity Type Tests for IEEE 1613
NOTE
The RUGGEDCOM RX1512 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires
error-free and interrupted communications.
HV Impulse
Dielectric Strength
Fast Transient
Oscillatory
Radiated RFI
ESD

Environmental Type Tests

Test
IEC 60068-2-1
EMC and Environmental Type Tests
Description
Ripple on DC Power Supply
Voltage Dips and Interrupts
Dielectric Strength
HV Impulse
Description
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Earth ground ports
Signal ports
DC Power Ports
Enclosure ports
Enclosure Contact
Enclosure Air
Cold Temperature
DC Power Ports
DC Power Ports
DC Power Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Description
Test Ad
Test Levels
300 V for 1 s
10%
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Failsafe Relay output)
2 kV
5 kV (Failsafe Relay output)
5 kV
Test Levels
5 kV (Failsafe Relay Output)
5 kV
2 kV
2 kV
± 4 kV @ 2.5 kHz
± 4 kV
2.5 kV common mode @1MHz
2.5 kV common
1 kV differential mode @ 1 MHz
35 V/m
± 8 kV
± 15 kV
Test Levels
-40 °C (-40 °F), 16 Hours
Chapter 6
Certification
Severity
Levels
3
Severity
Levels
37