Section 5.1
Power Supply Specifications
NOTE
When determining cable lengths, make sure the minimum input voltage for the power supply is
provided at the power source.
Power Supply Type
Internal
a
Power consumption varies based on the device configuration.
Section 5.2
Failsafe Relay Specifications
Maximum Switching Voltage
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
Power Supply Specifications
Input Range
Min
11 VDC
72 VDC
Rated Switching Current
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
Internal Fuse Rating
Max
6.3 A
Chapter 5
Technical Specifications
Maximum Power
a
Consumption
26.4 W
Isolation
1500 V
for 1 minute
rms
between coil and contacts