Mounting The Device On A Din Rail - Siemens RUGGEDCOM RX1512 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1512:
Table of Contents

Advertisement

RUGGEDCOM RX1512
Installation Guide
IMPORTANT!
Heat generated by the device is channeled outwards from the enclosure. As such, it is recommended
that 2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some
convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
NOTE
For detailed dimensions of the device with either DIN rail or panel hardware installed, refer to
Section 5.5, "Dimension Drawings"
CONTENTS
Section 2.3.1, "Mounting the Device on a DIN Rail"
Section 2.3.2, "Mounting the Device to a Panel"
Section 2.3.1

Mounting the Device on a DIN Rail

For DIN rail installations, the RUGGEDCOM RX1512 can be equipped with panel/DIN rail adapters pre-installed on
each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
To mount the device to a DIN rail, do the following:
1.
Align the adapters with the DIN rails and slide the device into place.
Figure 2: DIN Rail Mounting
1. Panel/DIN Rail Adapter    2. DIN Rail    3. Screw
2.
Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
Mounting the Device on a DIN Rail
.
3
2
1
Chapter 2
Installing the Device
1
2
7

Advertisement

Table of Contents
loading

Table of Contents