Fortinet FIM-7910E User Manual

Interface module

Advertisement

Quick Links

7000
FIM-7910E Interface Module Guide

Advertisement

Table of Contents
loading

Summary of Contents for Fortinet FIM-7910E

  • Page 1 7000 FIM-7910E Interface Module Guide...
  • Page 2 FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET BLOG https://blog.fortinet.com CUSTOMER SERVICE & SUPPORT https://support.fortinet.com  http://cookbook.fortinet.com/how-to-work-with-fortinet-support/ FORTIGATE COOKBOOK http://cookbook.fortinet.com FORTINET TRAINING SERVICES http://www.fortinet.com/training FORTIGUARD CENTER http://www.fortiguard.com FORTICAST http://forticast.fortinet.com END USER LICENSE AGREEMENT http://www.fortinet.com/doc/legal/EULA.pdf FEEDBACK Email: techdocs@fortinet.com Friday, June 23, 2017 FIM-7910E Interface Module Guide 01-540-374567-20170623...
  • Page 3: Table Of Contents

    Installing CFP2, SFP+, and SFP transceivers To install transceivers FIM-7910E mounting components Inserting a FIM-7910E module into a chassis Shutting down and removing a FIM-7910E board from a chassis Troubleshooting FIM-7910E does not startup FIM-7910E status LED is flashing during system operation...
  • Page 4: Fim-7910E Interface Module

    FPM processor modules. The FIM-7910E can be installed in any FortiGate-7000 series chassis. Normally you would install two FIM-7910E modules in chassis hub/switch slots 1 and 2. Two FIM-7910Es provide a total of four C form-factor pluggable 2 (CFP2) interfaces for a FortiGate-7000 chassis.
  • Page 5: Physical Description

    -31 to 158°F (-35 to 70°C) Relative Humidity 10% to 90% (Non-condensing) Front panel LEDs From the FIM-7910E font panel you can view the status of the module LEDs to verify that the module is functioning normally. State Description The FIM-7910E is powered off.
  • Page 6: Front Panel Connectors

    Connection at 10Mbps. Front panel connectors You connect the FIM-7910E to your 100Gbps networks using the C1 to C4 front panel CFP2 interfaces. The front panel also includes M1 and M2 SFP+ interfaces for the base channel, four Ethernet management interfaces FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 7: Supported Transceivers And Breakout Cables

    You can split the interfaces of the FIM-7910Es in slot 1 and slot 2 at the same time by entering a single CLI command. Splitting the interfaces requires a system reboot so Fortinet recommends that you split multiple interfaces at the same time according to your requirements to avoid traffic disruption.
  • Page 8: Turning The Module On And Off

    FIM-7910E interface module For example, to split the C1 interface of the FIM-7910E in slot 1 (this interface is named 1-C1) and the C1 and C4 interfaces of the FIM-7910E in slot 2 (these interfaces are named 2-C1 and 2-C4) connect to the CLI of your...
  • Page 9 FIM-7910E interface module FIM-7910E hardware architecture FIM-7910E hardware architecture Data Management Heartbeat (C1 - C4) (MGMT1-4) (M1 M2) Integrated Switch Fabric Chassis Fabric Backplane Chassis Base Backplane FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 10: Hardware Installation

    This chapter describes installing a FIM-7910E interface module into a FortiGate-7000 chassis. Installing CFP2, SFP+, and SFP transceivers You must install CFP2 transceivers into the FIM-7910E front panel C1 to C4 fabric channel interfaces before connecting them to 100Gbps networks. See...
  • Page 11: Fim-7910E Mounting Components

    (when open the latch slides up about 2 mm) The FIM-7910E handles align the module in the chassis slot and are used to insert and eject the module from the slot. The latches activate micro switches that turn on or turn off power to the module. When both latches are raised the module cannot receive power.
  • Page 12: Inserting A Fim-7910E Module Into A Chassis

    If the module is not receiving power all LEDs remain off. FIM-7910Es are hot swappable. The procedure for inserting a FIM-7910E into a chassis slot is the same whether or not the chassis is powered on.
  • Page 13 In the photograph an FIM-7910E module is being installed into chassis slot 1 of a FortiGate-7040E chassis. 2. Unlock the left and right handles by pushing the handle latches up about 2 mm until the handles pop open.
  • Page 14 Inserting a FIM-7910E module into a chassis Hardware installation 3. Carefully slide the module into the slot until the handles engage with the sides of the chassis slot, partially closing them. Insert the module by applying moderate force to the front faceplate (not the handles) to slide the module into the slot.
  • Page 15 Hardware installation Inserting a FIM-7910E module into a chassis 5. Tighten both retention screws to secure the module in the chassis. You can tighten the retention screws by hand with a Phillips screwdriver. If you use a power screwdriver the tightening torque needs to be adjusted between 3 In-lb to 4 In-lb (0.4 N-m to 0.48 N-m).
  • Page 16 Inserting a FIM-7910E module into a chassis Hardware installation As the latches are locked, power is supplied to the module. If the chassis is powered on during insertion the status LED flashes green as the module starts up. Once the module has started up and is operating correctly, the front panel LEDs are lit for normal operation.
  • Page 17: Shutting Down And Removing A Fim-7910E Board From A Chassis

    Disconnect all cables from the FIM-7910E module, including all network cables and USB cables or keys. FIM-7910Es are hot swappable. The procedure for removing a FIM-7910E from a chassis slot is the same whether or not the chassis is powered on.
  • Page 18 Shutting down and removing a FIM-7910E board from a chassis Hardware installation 1. Fully loosen the retention screws. You must fully loosen the screws or the handles may be damaged when used to eject the board from the chassis slot.
  • Page 19 Hardware installation Shutting down and removing a FIM-7910E board from a chassis 3. Fully open the handles to eject the module from the chassis. You need to open the handles with moderate force to eject the module from the chassis.
  • Page 20: Troubleshooting

    Latches and handles not fully closed If the latches or handles are damaged or positioned incorrectly the FIM-7910E may not start up. Make sure the latches are fully closed and the handles are correctly aligned, fully inserted and locked and the retention screws are tightened.
  • Page 21: Quick Fim-7910E Configuration

    CLI. You can connect to the GUI using HTTP or HTTPS, You can connect to the CLI using SSH or Telent or by a direct console connection to the FIM-7910E Console port. Use a terminal emulator with the following settings to connect to the console port: bits per second: 9600, data bits: 8, parity: none, stop bits: 1, flow control: none.
  • Page 22 Changing network settings Quick FIM-7910E configuration At any time during the configuration process, if you run into problems, you can reset the FIM-7910E to the factory defaults and start over. From the CLI enter execute factoryreset. Connect to the GUI by connecting MGMT1 of the module in slot 1 to your network and browsing to https://192.168.1.99.
  • Page 23: Cautions And Warnings

    Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 24: Safety

    Attention: Débranchez les cordons de la source d’alimentation avant tout entretien. Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning / surge protector, and be properly grounded. Use an electrostatic discharge workstation FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 25 Fiber optic transceiver must be rated 3.3V, 22mA max, Laser Class 1, UL certified component. Le transceiver optique doit avoir les valeurs nominales de 3.3 V, maximum 22 mA, Laser Class 1, homologué UL FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 26: Regulatory Notices

    European Conformity (CE) - EU This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 27: Voluntary Control Council For Interference (Vcci) - Japan

    此 为 A级 产 品 , 在 生 活 环 境 中 , 该 产 品 可 能 会 造 成 无 线 电 干 扰 。 这 种 情 况 下 , 可 能 需 要 用 户 对 其 采 取 切 实 可 行 的 措 施 。 FIM-7910E Interface Module Guide Fortinet Technologies Inc.
  • Page 28 Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features, or development, and circumstances may change such that any forward-looking statements herein are not accurate.

Table of Contents