Wolf TGB-40 Maintenance Instructions Manual page 44

Gas fired wall-mounted boiler
Hide thumbs Also See for TGB-40:
Table of Contents

Advertisement

Available languages

Available languages

• Release the nut inside the combustion chamber, if
necessary counter-lock the screw.
• Remove the pot.
• With the burner, push the insulation from the bottom up
and out.
To do this, invert the heat exchanger on the floor and
carefully push down from the top.
44
TGB-40/60 Maintenance instructions
Combustion chamber pot inside the heating water heat
exchanger
Remove the pot
Pushing out the insulation with the burner
Two part insulation pushed out of the heat exchanger
Combustion
chamber pot