JBW50W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current
Maximum output power
Input conditions
∗2
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
Output characteristics
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Overvoltage threshold Edc
Overcurrent threshold
Source effect
Load effect
Voltage
Temperature effect
stability
Drift(Time effect)
Recovery
Ripple Ep-p
Ripple noise Ep-p
Start up time
Hold up time
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Parallel operation
Series operation
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
Constructions
External dimensions
Weight
Mounting method
Case material
∗1
Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
∗2
Please note that the deterioration of parts is occasionally caused when operating for a long time(over 10 minutes) with the voltage below the range of the
input voltage.
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.
JBW05-10R
∗1
5V • 10A
W
50
V
85 to 265[Rating: 100 to 240]/120 to 375
Hz
47 to 66[Rating: 50 to 60](Single phase)
A
0.7typ./0.88max. [AC.100V]0.35typ./0.5max.[AC.240V]
A
3.15[AC.250V, built-in]
A
15typ.(30max.)[AC.100V]40typ.(60max.)[AC.240V] cold start
mA
0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]
0.99typ./0.93typ.[AC.100/240V]
%
77typ.[AC.100V]
%
79typ.[AC.240V]
V
5
V
4.5 to 5.5
A
10
A
0
V
5.75 to 6.9
A
10.5min.
%
0.4max.[Within the input voltage range]
%
0.8max.[0 to 100% load]
%
1max.[Ambient temperature: –10 to +50°C]
%
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
%
±4max.[50 to 100% sudden load change]
mV
80max.
mV
120max.
ms
500max.(400typ.)/500max.(400typ.) [AC.100/240V]
ms
20typ./20typ. [AC.100/240V]
No
Voltage shut-down type.
Rectangular type, automatic recovery.
No
No
Impossible
Possible
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
EN61000-3-2 meet.
mm
26× 55× 190[H× W× L]
g
220max.
Can be attached to 1 side.
No(PWB Material: CEM3)
JBW12-4R3
JBW15-3R5
12V • 4.3A
15V • 3.5A
51.6
52.5
80typ.[AC.100V]
80typ.[AC.100V]
81typ.[AC.240V]
81typ.[AC.240V]
12
15
10.8 to 13.2
13.5 to 16.5
4.3
3.5
0
0
13.8 to 16.8
17.2 to 21
5.4min.
4.4min.
120max.
120max.
150max.
150max.
(8/30)
JBW24-2R1
24V • 2.1A
50.4
81typ.[AC.100V]
83typ.[AC.240V]
24
21.6 to 26.4
2.1
0
27.6 to 33.6
2.7min.
120max.
150max.
004-02 / 20070523 / ea122_jbw.fm

Advertisement