RB-6 L-801A (Airport) Rotating Beacon (Export)
Problem
2. Lamp not lighting
3. Photocell not
operating
4. Poor beacon visibility
5. Motor not turning
6. Motor not turning
during cold weather
7. Heater not operating
 2001 Siemens Airfield Solutions, Incorporated
All rights reserved
Possible Cause
Lamp defective
Blown fuse
Photocell inoperable
Brush assembly not working
Loose or broken wire
Photocell defective
Relay defective
Loose or broken wire
Lamp filament not at focal point of
reflector
Dirty lenses
Blown fuse
Motor relay defective
Motor defective
Shaft bearing seized
Loose or broken wire
Heater inoperable
Blown fuse
Thermostat defective
Heater defective
Loose or broken wire
96A0221B
Issued 5/01
Troubleshooting
Corrective Action
Replace lamp. Refer to Replacing Lamp in
the Maintenance section.
Replace fuse F2 (30 A, Slo-Blo).
See Photocell not operating in this table.
Replace brush assembly. Refer to Replacing
Brushes and Brush Brackets in the
Maintenance section.
Replace cordset or socket.
Replace photocell.
Replace relay.
Repair or replace wire.
Move socket up or down so the lamp filament
is at the focal point of the reflector.
Clean lenses after they cool off.
Replace fuse F1 (3.2 A, Slo-Blo).
Replace relay.
Replace motor.
Replace defective bearing.
Repair or replace wire.
Refer to Heater not operating in this table.
Replace fuse F3 (5 A, Slo-Blo).
Replace thermostat.
Replace heater.
Repair or replace wire.
Page 5-2