EDITING CONTROL UNIT BVE-700A INSTALLATION MANUAL 1st Edition (Revised 1) Serial No. 10001 and Higher...
Page 2
4. Prevention against achieving hazardous condition due to uneven mechanical loading When this product is installed in a rack, please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading. BVE-700A...
Manual Structure Purpose of this manual This manual is the installation manual of Editing Control Unit BVE-700A. This manual is intended for use by trained system and service engineers, and describes the information on installing the BVE-700A. Related manuals Beside this Installation Manual, the following manuals are available for the unit.
. Plugging the power cord in the AC inlet, push as far as it will go. Ventilation The inside of the BVE-700A is air-cooled by a fan (on left For customers in the U.S.A. and Canada side). 1 Power cord, 125 V 10 A (2.4 m) : ! 1-557-377-11...
1-4. Matching Connectors and Cables Use the following connectors, cables, or equivalents when connecting cables to the unit. Panel indication Connector name Matching connector and cable Name Sony part No. Processor unit PLAYER-1 D-sub 9-pin, Female D-sub 9-pin, Male PLAYER-2...
No Connection EDL : RS-232C (D-sub 9-pin, Male) _ EXT VIEW _ Pin No. Signal Function No Connection Received data Transmitted data No Connection Ground No Connection (Not used at present) (Not used at present) No Connection 1-5 (E) BVE-700A...
Page 10
Ground Ground Ground NETWORK : 10BASE-T/100BASE-TX (8-pin, Modular jack) _ EXT VIEW _ Pin No. Signal Function Transmitted data (+) Transmitted data (_) Received data (+) No Connection No Connection Received data (_) No Connection No Connection 1-6 (E) BVE-700A...
Any switch setup other than the these shown on the above table is invalid. S901-6 : Factory use S901-7 : Setup status OPEN : Normal operation CLOSE : The machine starts up with the setup of USER SETUP DATA1 state. 1-7 (E) BVE-700A...
Page 12
D1700 (H-5) TEMP Blinks in green when the temperature in Lights off the BVE-700A turns 85 °C or higher. At the same time, TEMP ERROR is displayed on the scratchpad on the control panel. D1702 (H-4) Lights up in green when the temperature in Lights off the BVE-700A turns 45 °C or higher.
The BVE-700A is mounted in the 19-inch standard rack. the RMM-10 rack mount kit. To mount the BVE-700A in the rack, use the specified rack mount kit and follow the procedure described below. Tighten the screws to the following torque.
Rack tool Rail Rail B5 x 12 9. Attach the front panel to the equipment. 1-8. Installing the BKE-701A For the installation procedure, refer to “4. Installing the BKE-701A” of the Installation Manual supplied with the BKE-701A. 1-10 (E) BVE-700A...
This may have an Protrusions adverse effect on performance and the life of the machine. Cleaning of the fan every month is recommended. Contact your local Sony Sales Office/Service Center for information on cleaning the fan. Grooves Front panel...
A large capacitor is installed on the CA-67 board in order to retain the various data in the BVE-700A machine. Leave the main power of the BVE-700A turned on for about four hours or longer in order to charge this capacitor.
Page 17
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.