IKEA MATMÄSSIG Manual page 18

Hide thumbs Also See for MATMÄSSIG:
Table of Contents

Advertisement

ENGLISH
For more information on injector
replacement, refer to the Technical data
chapter.
Warning! Conversion or
replacement can only be
performed by a authorised
technician.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
3. Using a socket spanner 7, unscrew and
remove the injectors, and replace them
with the ones required for the type of
gas in use.
4. Reassemble the parts, following the
same procedure backwards.
Place the label with relevant
information for new type of gas
close to the supply pipe before
sealing the appliance. If the
appliance is already sealed
please stick it directly on the user
manual booklet, after Technical
data chapter, and close to the
rating plate drawing.
You can find this label in
package supplied with
appliance.
If the feeding gas pressure is
different or variable from the
required one, you must install an
appropriate pressure adjuster,
which is not supplied with the
product. If needed, it must be
ordered separately from the
local After Sales Service Provider,
refer to the Service chapter. The
pressure adjuster must be fitted
on gas supply pipe, in
compliance with the rules of the
force.
The rating plate is located below the
surface of the casing.
Adjusting flame level
When you install the hob, it is necessary to
check the minimum flame setting:
1. Turn the gas tap to the maximum
position and ignite.
2. Set the gas tap to the minimum flame
position and turn the control knob from
minimum to maximum several times. If
the flame is unstable or extinguished,
follow the procedure further.
3. Re-ignite the burner and set to
minimum.
4. Remove the control knob .
5. To adjust, use a thin bladed screwdriver
and turn the adjustment screw until the
flame is steady and does not extinguish
when the knob is turned from minimum
to maximum, and vice versa (see
following picture).
6. Repeat this procedure for all burners.
7. Reassemble the knobs.
Warning! If the appliance is
connected to liquid gas (G31
propane or G30 butane), the
regulation screw must be
fastened as tightly as possible.
18