All connections shall be made and water added before performing this function.
First ignitions immediately after installation, system will implement a self-learning procedure to reach correct
ignition level.

9.6 Prior to Commissioning:

• Check system pressure is correct;
• Power boiler;
• Open gas tap (positioned under boiler);
• Select required heating mode. See section 10.4 Operating Modes.

9.7 Commissioning For The First Time:

1.
Turn power to boiler on. Code "000" appears on the display. Appliance is ready for "commissioning" procedure.
2.
Press
at the same time. Hold for 6 seconds. "On" appears on the display for 2 seconds followed by code "312"
indicating "de-aeration" function is active. This function lasts 10 minutes.
3.
Boiler will turn on after deaeration function is complete. Display will show code "000" alternating with % of ignition power and
temperature value (°F / °C).
• During this gas recognition function phase which lasts about 7 minutes, type of gas being used is analyzed.
• During this function, assure maximum heat exchange to heating or DHW system (domestic hot water demand) by having all
heating zones open or all domestic hot water taps open, in order to prevent boiler from switching off due to overheating.
• If boiler operates on Gas A (Natural Gas), display shows NG (Natural Gas) for about 10 seconds. Boiler is now ready for
normal operation.
• If display shows LPG (Gas E), press
factory setting. Boiler will stay set to Natural Gas.
• If boiler operates on Gas E (LPG) display shows LPG (Gas E). Press
• If display shows NG (Gas A) and does not recognize the type of gas used, press
at least 4 seconds to exit the function. Change parameter P02=01 as described in section 9.12 Parameter Settings of boiler
Installation, Operation and Maintenance Manual. Perform Automatic Calibration Function. Manual Calibration may be
necessary if combustion is not within specified range.

9.8 Automatic Calibration Function

Before performing this function verify there are no heat demands in progress.
During this function ensure there is maximum heat exchange to the system in Heating or DHW mode (DHW request) to avoid boiler
shutting off due to overheating.
Press
and
together and hold for about 6 seconds. When display indicates "On" press
pressing previous buttons.
NOTE: Boiler must not shutoff during calibration. Open all heating zones in heating or DHW mode
to ensure boiler does not shutoff.
Important: If display indicates "303" Automatic Calibration function has not been activated. Disconnect boiler
from main power supply for few seconds and repeat procedure.
1.
When function is enabled,
2.
After ignition sequence, which can also take place after few attempts, boiler performs three operations. Each operation lasts
about 1 minute:
• maximum power
• ignition power
• minimum power
3.
Before moving to the following phase, from maximum power to ignition power and then to minimum power.
on the display.
4.
During this phase, power level reached by boiler and delivery temperature alternate on the display.
5.
flash together on the display, automatic calibration function has completed.
When
,
and
6.
Press
to exit the function. Display will show ESC.
7.
Verify combustion is within specified range. If not, perform Automatic and then Manual Calibration. (See Section 9.8)
240012485 REV C [06/30/2019]
NOTICE
NOTICE
and
together and hold down for at least 4 seconds to exit without changing
NOTICE
will flash on the display.
and
for at least 6 seconds to confirm gas used.
and
44
together and hold down for
within 3 seconds after
and
appear