Sundance Spas 780 Owner's Manual page 13

780 series
Hide thumbs Also See for 780:
Table of Contents

Advertisement

US/Canada 2-Pump Palermo / Bahia Models (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In 50A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed. This is
the factory setting.
** In 30A configuration, the heater will not operate while either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** in 60A configuration, the heater will operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.
Export 1-Pump Cayman / Lagunas Models (50Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In the 20A configuration, the heater will not operate at the same time as
the main jets pump. This is the factory setting.
** In the 30A configuration, the heater will operate at the same time as
the main jets pump.
Export 2-Pump Palermo / Bahia Models (50Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In 20A configuration, the heater will not operate while either jets
is running in high speed.
runs only in high speed.
** In 30A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
In 40A configuration, the heater will operate while either jets pump
***
is running in high speed. Note: pump 2 runs only in high speed.
240V/50A*
240 VAC
3
60Hz
36A
50A, 2-Pole
230V/20A*
230 VAC
3
50Hz
15A
20A
230V/20A*
230 VAC
3
50Hz
15A
20A
This is the factory setting.
240V/30A**
240 VAC
3
60Hz
24A
30A, 2-Pole
230V/30A**
230 VAC
3
50Hz
21A
30A
230V/30A**
230 VAC
3
50Hz
23A
30A
240V/60A***
240 VAC
3
60Hz
43A
60A, 2-Pole
230V/40A***
230 VAC
3
50Hz
29A
40A
pump
Note: pump 2