YASKAWA V1000 Replacing Manual page 11

Procedure for replacing the v1000 with the ga500
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

Analog Input
V1000
GA500
H1
H1
H2
HC
HC
MA
MA
MB
MB
MC
MC
P1
P1
C1
*8
P2
P2
C2
*8
PC
*8
MP
MP
AM
AM
AC
AC
PS
*1: When replacing the wiring to SC terminal of the V1000 with that of the GA500, see the connection diagram in Table 7.
*2: Factory default = Sinking Mode: SC
*3: Factory default = Sinking Mode: SN (short-circuit SC-SP)
*4: To select the input method, use DIP switch S1 and H3-09 [Terminal A2 Signal Level Select].
*5: Remove the jumper between H1 and HC to use the Safe Disable input.
*
6: Minimum OFF width: Time from the Safe Disable input to the output shut-off.
*7: Remove the jumper between H1-HC and H2-HC to use the Safe Disable input.
*8: The wiring to the V1000 PC terminal should be connected to the GA500 C1 or C2 terminal.
*9: Connect a flywheel diode when driving a reactive load such as a relay coil. Make sure that the flywheel diode rating is not
lower than the circuit voltage.
*10: Factory default = Output frequency
*11: Factory default = Output frequency
*12: Use jumper switch S5 and H4-07 [Terminal AM Signal Level Select] to set the signal type.
Name
Safe Disable input 1
Safe Disable input 2
 Safe Disable function common
 Safe command common
N.O. output (error)
N.C. output (error)
Digital output common
Multi-function PHC output 1
Note: Factory default function
V1000: During Run
GA500: During Run
Multi-function PHC output 2
Note: Factory default function
V1000: Frequency Agree
GA500: Frequency (Speed) Agree
Photocoupler output common
Pulse Train Output
*10
Multi-function analog monitor 1
*11
Monitor common
External 24 V power supply input
Signal Level
V1000
 24 VDC, 10 mA
maximum
 ON (closed): Normal
operation
 OFF (open): Coasting
 Internal impedance 3.3
 Minimum OFF width:
1ms or less
*5
*6
Safe Disable function common
Note: Do not short-circuit the terminals HC and SN
 Relay output
 30 VDC 10 mA to 1 A
 250 VAC 10 mA to 1 A
 Photocoupler output
 48 V, 50 mA maximum
*9
32kHz max.
 0 to +10 V
 2 mA maximum
0 V
Supplies backup power to the drive control circuit, keypad,
and option board. 21.6 VDC to 26.4 VDC, 700 mA
VAN-V19001E [V1000→GA500]
GA500
 24 VDC, 6 mA
maximum
 ON (closed): Normal
operation
 OFF (open): Coasting
 Internal impedance:
4.7kΩ
 Minimum OFF width:
3ms or less
*7
 Photocoupler output
 48 V, 2 mA to 50 mA
*9
 0 to +10 V/0% to 100%
 4 to 20 mA (receive-
side recommended
impedance: 250Ω)
*12
11/35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500

Table of Contents