General Specifications - BW Technologies GasAlertClip Extreme Instruction Sheet

2 or 3 year gas detector
Hide thumbs Also See for GasAlertClip Extreme:

Advertisement

Accessories
Test cap and hose: GA-TC-1
Infrared handheld printer: GPR-PRINTER2*
Printer paper replacement, 3 rolls: GPR-PP-K4
Automatic test station: GA-TS02
GasAlertClip Extreme MicroDock II docking module:
H = Hydrogen sulfide docking module
M = Carbon monoxide docking module
S = Sulfur dioxide docking module
X = Oxygen docking module
Consult your sales representative for complete order numbers and full descriptions.
MicroDock II automatic test/calibration station: DOCK2-2-##-##
IR DataLink: GA-USB2
Neck strap with safety release: GA-NS-1
Alligator clip (non-conductive): GA-AG-1
Alligator clip (stainless steel): GA-AG-2
Hard hat clip: GA-HC-
1
(
for use with alligator clip GA-AG-1 or
GA-AG-2)
Belt clip: GA-CL-1
Portable product training video: GA-CDT1
GasAlertClip CD-ROM instructions: GA24XT-CDM
*For delivery with 220 VAC charger, add suffix (-UK) for United Kingdom, (-EU) for
European, and (-AU) for Australian.

General Specifications

1 year before activation
Shelf life
Weight
76 g (2.7 oz.)
Instrument
28 x 50 x 81 mm (1.1 x 2.0 x 3.2 in.)
dimensions
S: −40 to +50
o
C / −40 to +122
Operating
H
2
CO: −30 to +50
o
C / −22 to +122
temperature
: −30 to +50
C / −22 to +122
o
SO
2
: −20 to +50
C / −4 to +122
o
O
2
Internal vibrating operates to: −15
Operating humidity
5% to 95% relative humidity
(non-condensing)
≈ 95 dB at 30 cm (1 ft.)
Audible alarm
Visual alarm
Flashing, wide-angled alarm lens with quad red
LEDs plus alarm LCD readout.
Display
Liquid crystal display (LCD)
Sensor type
Electrochemical cells
Detection technique
Instantaneous alarm
Battery
Lithium, non-replaceable
Classified by UL to both U.S. and Canadian
Ratings and
Standards as intrinsically safe for Class I, Division
certifications
1, Group A, B, C, D and Class I, Zone 0, Group IIC
:
g
ATEX
CE 0539
II 1 G EEx ia IIC T4
DEMKO 03 ATEX 0321968
IECEx
CE: European Conformity
ABS Type Approved VA-348-169-X
IP 66/IP 67
Ingress protection
Complies with EMC Directives 89/336/EEC
EMI/RFI
Safety Specifications
Maximum operating
life
Detection range
o
F
o
F
o
F
Alarm setpoints
o
F
Calibration
o
o
C / +5
F
Note: This product has been classified for use in atmospheres not more
than 21% v/v O
Event Logging Specifications
Number of stored
events
Data transmission
method
Information
transmitted
Data transmission
time
24 Month Detector: 2 years after activation,
assuming 3-5 minutes of alarm time/day
36 Month Detector: 3 years after activation,
assuming 1 minute of alarm time/day
H
S: 0 to 100 ppm
2
CO: 0 to 300 ppm
O
: 0 to 30% by volume
2
SO
: 0 to 100 ppm
2
Instant low and instant high
H
S, CO, SO
: Not required
2
2
O
: Self-calibrating
2
.
2
Up to ten events encountered. If more than ten, the
older event are replaced by the newer events.
Via infrared port to thermal printer or via IR Datalink
to PC (for ordinary locations only)
Serial number
Life remaining
Self-tests performed
Total number and duration of all events
encountered
Last ten events:
Maximum exposure, MicroDock bump check, or
O2 calibration
Data shown for maximum exposures and bump
checks:
Gas type and alarm level in ppm or %
Time elapsed since the alarm occurred in days,
hours, and minutes
Duration of alarm in minutes and seconds
45 seconds plus 10 seconds per record