MAXIMUM TEMPERATURE OF THE PUMPED FLUID
MAXIMUM/MINIMUM AMBIENT TEMPERATURE
MAXIMUM NUMBER OF STARTS PER HOUR
MAXIMUM SUCTION HEIGHT (recommended)
MAXIMUM SUCTION HEIGHT (recommended)
MAXIMUM ADMITTED WORKING PRESSURE
MAXIMUM ADMITTED WORKING PRESSURE
MAXIMUM ADMITTED WORKING PRESSURE
*below 5° C, drain the electropump to prevent failures or damages caused by frost
Model
MAX 80/48
AUTOMAX 80/48
MAX 80/60
MAX 120/60
AUTOMAX 120/60
JET 600
JET 800
JET 1000
NEWJET 40/40
NEWJET 45/43
NEWJET 60/50
** Sound emission values obtained in conformity with the EN 12639 standard **Measurement method according to EN ISO 3744
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
WARNING
DANGER
Use a suction pump (2) with a diameter equivalent to that of the suction mouth of the electropump (1).
If the height (HA) is over 4 meters use a tube with a larger diameter. The suction line should be perfectly airtight. No
elbows and/or slopes should be present to prevent the formation of air locks that could affect the electropump efficiency.
A foot valve (3) with filter (4) should be fitted at about half a metre below the fluid that has to be pumped (HI) on one end
of the line. Load losses can be reduced using delivery piping with a diameter equivalent or greater than the electropump
mouth (5). It is advisable to install a check valve (6) directly on the delivery line to prevent the electropump being damaged
by "water hammer".
The pump cannot be used for sea water and inflammable, corrosive, explosive or
dangerous liquids.
Verify that the electropump never runs without liquids.
(Lwa)**
Lpa
66 dB
58,1 dB
69 dB
61,3 dB
73 dB
64,6 dB
75 dB
68,1 dB
86 dB
78,01 dB
78 dB
69,7 dB
85 dB
72,7 dB
When installing, please ensure electropump is disconnected from
electrical supply. Pumps in this series are not suitable for use in a
swimming pool and the relevant cleaning and servicing operations.
Protect the electropump and all pipes from bad weather or freezing conditions.
To prevent possible injuries to people, avoid inserting hands into the mouth of the
pump if this is connected to the mains.
50° C
40°/ 5° C*
40 uniformly distributed
9 m (jet/newjet/jetinox/autojet)
7 m (max/multinox-a/automax)
6 bar (jet/newjet/jetinox/autojet)
7 bar (max)
9 bar (multinox-a)
Model
MULTINOX A 200/40
MULTINOX A 200/52
MULTINOX A 200/65
MULTINOX A 200/80
JETINOX 45/43
JETINOX 60/50
AUTOJET 60/50
JETINOX 70/50
AUTOJET 70/50
JETINOX 90/43
JETINOX 90/50
2
GB
GB
(Lwa)**
Lpa
79 dB
66,5 dB
78 dB
69,7 dB
85 dB
72,7 dB
82 dB
70,1 dB
91 dB
83,2 dB