Mechanical Stability (In Operation); Cable Lengths; Switching Properties - Siemens SCALANCE XR-300WG Series Operating Instructions Manual

Simatic net. industrial ethernet switches
Hide thumbs Also See for SCALANCE XR-300WG Series:
Table of Contents

Advertisement

7.4

Mechanical stability (in operation)

The following technical specifications apply to the following devices:
● SCALANCE XR324WG
● SCALANCE XR328-4C WG
IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
7.5

Cable lengths

The cable lengths listed below apply to the SCALANCE XR-300WG.
Cable
IE TP torsion cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
IE FC TP Marine / Trailing / Flexible cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP Marine / Trailing / Flexible cable
with IE FC RJ-45 Plug 180
IE FC TP standard cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 Plug 180
7.6

Switching properties

The switching properties listed below apply to the SCALANCE XR-300WG.
Switching properties
Aging time
Maximum frame size
Max. number of learnable ad-
dresses
Response to LLDP frames
Response to spanning tree
BPDU frames
CoS acc. to IEEE 802.1Q
SCALANCE XR-300WG
Operating Instructions, 05/2017, C79000-G8976-C454-01
Can be configured (default value: 30 seconds)
1632
16382
Blocking
Forwarding
Yes
7.4 Mechanical stability (in operation)
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
Technical specifications