Fitting the thermal insulation
Note
The cover strip is held in its vertical
position by the wound capillaries.
This is necessary for the rest of the
installation.
3. Route the thermometer sensor capil-
laries to the back of the cylinder.
Note
Repeat the following steps subject to
the number of installed thermome-
ters.
4. Depending on the fitting location,
secure the thermometer sensor in the
clamping bracket or pull the sensor
retainer out of the sensor well.
Installation sequence
(cont.)
5. Secure the sensor on the outside of
the contact spring of the sensor
retainer so that it is flush with the front
of the spring.
6. Secure the thermometer sensor
capillaries.
Note
Never wrap insulating tape around
the thermometer sensor.
7. Insert sensor retainer as far as it will
go.
11