Application; Unit Components; Cbx40Uhv Control Box; Control Box - Lennox CBX40UHV Series Installation And Service Procedure

Hide thumbs Also See for CBX40UHV Series:
Table of Contents

Advertisement

LIMIT
RELAY
RELAY
CIRCUIT BREAKER

APPLICATION

CBX40UHV air handlers are designed for HFC-410A
applications only. All major air handler components
must
be
matched
recommendations for the unit to be covered under
warranty. Refer to the Engineering Handbook for approved
system matchups. A misapplied system will cause erratic
operation and can result in early unit failure. The units come
with factory installed check and expansion valve for all
applications. It has been installed internally and is accessible if
required.
ELECTROSTATIC DISCHARGE (ESD)
PRECAUTIONS AND PROCEDURES
CAUTION
Electrostatic discharge can affect electronic compo­
nents. Take precautions during unit installation and
service to protect the unit's electronic controls. Pre­
cautions will help to avoid control exposure to electro­
static discharge by putting the unit, the control and the
technician at the same electrostatic potential.
Neutralize electrostatic charge by touching hand and
all tools on an unpainted unit surface before perform­
ing any service procedure.
CBX40UHV
LIMIT
Figure 2. CBX40UHV Control Box
according
to

UNIT COMPONENTS

The CBX40UHV control box is shown in figure 2. Line
voltage and electric heat connections are made in the
Lennox
control box. Optional electric heat fits through an opening
located in the center of the control box. When electric heat
is not used, knockout plates cover the opening. The electric
heat control arrangement is detailed in the electric heat section
of this manual.
Low voltage connections are made on the air handler
control (AHC) also located in the control box. All AHC will
have factory installed clippable links connecting DS to R, R
to O and Y1 to Y2. These links will have to be removed in
certain unit application. See table 1.
Application
Harmony IIIt
Heat Pump
Two-Stage Cooling
All CBX40UHV series units use a single line voltage to
24VAC transformer mounted in the control box. The
transformer supplies power to the control circuits in the
indoor and outdoor unit. Transformers are rated at 70VA.
208/240VAC single‐phase transformers use two primary
voltage taps.
Page 9
HEATING ELEMENTS
HEATING ELEMENTS
AIR HANDLER CONTROL

Control Box

Table 1. Links
Remove Links
DS to R
R to O
Y1 to Y2