Error Code / Recall Mode - Lennox CBX40UHV Series Installation And Service Procedure

Hide thumbs Also See for CBX40UHV Series:
Table of Contents

Advertisement

4. Error Code / Recall Mode

To enter Error Code Mode, push
and hold button next to single
character LED display until solid
E symbol appears,
release
button.
Control will display up to ten error codes stored in
memory. If E 0 0 0 is displayed, there are no stored error
codes.
E
0
0
To exit Error Code Recall Model, push and hold button next
to single character LED display until solid three horizontal
bars appears, then release button.
NOTE — Error Codes are not cleared from memory.
Yes
E
0
- -
-
Figure 40. Error Code / Recall Mode
AHC in Idle Mode
(No heating cooling or indoor fan
operation)
To clear error codes stored in memory,
continue to hold push button while the solid
three horizontal bars are displayed. Release
button when solid is displayed.
Solid c starts blinking on
The display will blink for up to ten seconds. During this time, press the button
and release to confirm deletion of the error code history. As confirmation,
AHC will display 0 0 0 0 . (If ten second period expires or push button is
not released, control will automatically exit Error Code Mode and go into
mode without deleting error code history.
NOTE — Once the error code history is deleted, it cannot be recovered.
Page 50
No
Turn room thermostat to OFF
c
single character LED
display.
0
0
0
0
- -
-
CBX40UHV

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbx40uhv-024Cbx40uhv-030

Table of Contents