Features & Operating Controls - Wells WVAE-30F Supplemental Service Instructions

Fryer ventilator hood section
Hide thumbs Also See for WVAE-30F:

Advertisement

FEATURES & OPERATING CONTROLS
BACK VIEW
v.6
v.7
v.8
v.9
v.25
a.11
v.12
a.13
a.14
Note:
Items beginning with "a. ..." are part of the Ansul® fire suppression system
Items beginning "f. ..." are part of the FRYER
Items beginning "v. ..." are part of the VENTILATOR
f.1 POWER SWITCH
(FRYER - OFF - FILTER)
v.2 VENTILATOR POWER
LIGHT (green)
v.3 CHECK FILTERS
LIGHT (amber)
SIDE VIEW
f.17 a.18 a.19
a.10
a.15
FRYER
WVAE-30,
WVAE-55 or
WVPE-30
f.16
FRYER position turns ON the VENTILATOR POWER LIGHT and
BLOWER. If, within 10 seconds, there is sufficient AIR FLOW for
proper operation, the POWER LIGHT will remain ON and the fryer will
operate.
If, after 10 seconds, there is not sufficient AIR FLOW for proper
operation, the BLOWER and VENTILATOR POWER LIGHT will turn
OFF and the SERVICE REQUIRED LIGHT will turn ON.
Note: The POWER SWITCH must be turned OFF to reset the system
before the fryer can be operated.
Glows when the FRYER POWER SWITCH is ON.
Glows when GREASE BAFFLE and/or HEPA AIR FILTER are not
properly installed. When ON, the fryer heating elements are de-activated.
Make sure both the HEPA FILTER and the GREASE BAFFLE fully
depresses their respective filter sensor tang (f.25, lower left corner of the
filter rail), which proves the filters are in the proper position. When the filters
are in the proper position, the CHECK FILTER light will not be lit.
VENTILATOR WARNINGLIGHT PANEL
f.20
v.2
v.3
f.21
f.22
f.23
f.24
a.15
2
FRONT VIEW
v.4
v.5
f.1
f.26