3 Setting Up a Single-axis Servo System
Setting the Axis Parameters
Set the axis parameters for axis 0 based on the mechanical configuration of the system.
The input axis parameters are shown in the following table according to the mechanical configuration of
axis 0.
Icon on Settings Tab
Page
Unit Conversion Set-
tings
Operation Settings
1
Set the parameters on the Axis Parameter Settings Tab Page.
Click an icon on the Axis Parameter Settings Tab Page to display the settings for that particular
icon.
Set the axis parameters according to the data in the above table.
The following figure shows the axis parameters for the unit conversion settings.
3-12
Item
Unit of Display
Command Pulse Count Per Motor
Rotation
Work Travel Distance per Motor
Rotation
Maximum Velocity
Maximum Jog Velocity
Set value
mm
1,048,576
10.000 mm
500 mm/s
50 mm/s