User Interface/Control Box - Graco XM Series Repair Parts

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Repair

User Interface/Control Box

NOTE: This section covers all components included in
the wall power supply control box option and the
intrinsically safe pneumatic power supply control box
option.
Remove Shroud
1. Close main air shutoff valve on air supply line and
on system.
2. Remove shrouds (12, 13) covering control box.
Remove four nuts (14) and front shroud (12) first.
13
Replace Solenoid Module
Follow this procedure to replace a single solenoid
1. Remove shroud. See Remove Shroud.
2. Disconnect power.
3. Remove four nuts (4). Leave two nuts on left side of
panel tight. Open front panel of control box (11).
4. Disconnect solenoid cable connectors (242) from
solenoids.
22
5. Disconnect air tubing from solenoid manifold block
NOTE: If your sprayer is an intrinsically safe model, you
will need to remove the alternator air regulator from the
solenoid module. See Replace Alternator Regulator,
page 29, for removal instructions.
6. Remove two screws (210).
12
14
7. Remove and replace solenoid (209).
ti21276a
8. Reassemble screws (210) and solenoid cable
NOTE: From left to right, solenoid functions are as
follows:
11
4
ti21277a
(209).
connectors (242).
Dosing valve A (DVA) (normally open)
Dosing valve B (DVB) (normally open)
Pump A (PA) (normally closed)
Pump B (PA) (normally closed)
DVA
DVB
PA
PB
210
209
313289V

Advertisement

Table of Contents
loading

Table of Contents