3. Disassembly and Reassembly
3-3 Replacement of High Voltage Transformer
Parts
High Voltage
Transformer
PRECAUTION
Servicemen should remove their watches whenever working close to or replacing the magnetron.
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGHVOLTAGE
TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or near these
circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.
This document can not be used without Samsung's authorization.
Explaination Photo
14
Explaination
4.
Replace the High Voltage
Transformer
5.
After replace, reconnect the
leads correctly and firmly.