Service and maintenance
8.1
Removing material accumulation
To ensure that the belt scale will provide optimal accuracy, periodically inspect the area around
the calibration weights and remove any material build-up.
The calibration weights must remain consistent to calibrate the scale correctly. If material
accumulates on top of them, the added weight will cause the calibration procedure to produce
poor results. The top surface of the calibration weight supports must also be kept clean for the
scale to produce accurate results.
Material should not accumulate inside the crank body housings under normal operating
conditions, but it is a good idea to inspect them periodically.
Note
Before starting a calibration procedure, be sure to check that there is no material
accumulation in the three areas described below.
①
②
③
Milltronics MWL Weight Lifter
Operating Instructions, 11/2011, 7ML19985CR03-03
top surface of calibration weights
top surface of calibration weight support
inside crank body housing
8