ROUBLESHOOTING
T
ROUBLESHOOTING
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED
TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF
COMMERCIAL COOKING EQUIPMENT. HOWEVER, TO ASSURE YOUR CONFIDENCE,
CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE
ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.
Warranty will be void and the manufacturer is relieved of all liability if service work is performed by
other than a qualified technician, or if other than genuine Southbend replacement parts are installed.
When any difficulty arises it is always a good idea to check that the oven has been connected to the type of
voltage for which it was manufactured. The serial plate is located on the inside of the lower front panel. It
will list the type of voltage for which the unit was manufactured. In addition, a wiring diagram is attached to
the side of the fold down control panel, as well as reproduced in this manual (see page 38).
PERFORMANCE STANDARD
The typical time for the oven to heat from 75°F to 350°F is 7 to 8 minutes. The heating elements should
come on when the actual oven temperature drops to 10°F below the temperature setting.
TROUBLESHOOTING GUIDE
The left column of the following table lists symptoms that indicate a problem, while the center and right
columns list the possible causes and appropriate corrective action. Note that the recommendations of this
table assume that the wiring connections are good. When checking a component, always check the wiring
attached to the component as well.
Symptom
Possible Cause
Oven will not hold
Temperature probe not working.
correct temperature.
Temperature control not calling for heat.
Inadequate or improper ventilation.
Out of calibration.
Blower motor will not
No incoming electric power.
come on.
Loose wire connections.
Bad contactors.
Motor bad.
Shut down switch.
P
36
AGE
H
-S
ALF
!
WARNING
NOTICE
Check or Replace
Resistance across temperature probe leads at room temperature (70°F)
should be approximately 1096 ohms.
When heat is required, there should be continuity between terminals 6
and 7 on temperature control.
Check ventilation hood. Verify draw and make up air adjustment.
Calibrate according to procedure described on page 33.
Check incoming power.
Check wire connections.
Contactor pull in and supply power to motor. Verify contactor pulling in.
If power is being supplied but motor will not turn, replace motor.
All power except for motor supply come through shut down switch.