PIPE WORK ROUGHING IN DIMENSIONS
Pipe Work to
Solar Storage Tank
270 tank
320, 325 tanks
410 tank
Note: * the roughing in dimensions for B and C are 200 mm above fitting to allow room for
bends and valve installation.
Electric Boost
Solar Storage Tanks (Open Circuit)
A
Capacity
Hot Outlet
(litres)
270
1190
325
1430
410
1600
34
B
C
Solar Hot
Solar Cold
Flow *
Return *
685
635
754
635
820
643
D
Cold Inlet
73
73
81