Troubleshooting - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

Seq
Symptom
1
Warm Drinks
System Not Running
2
Warm Drinks
Compressor - Running
3
Warm Drinks
Compressor - Running
4
Warm Drinks
Compressor - Not Running
5
Warm Drinks
Compressor - Not Running
6
Warm Drinks
Compressor - Not Running
7
Warm Drinks
Compressor - Not Running
8
Warm Drinks
Compressor - Not Running
9
Warm Drinks
Compressor - Not Running
10
Warm Drinks
Compressor - Not Running
1
Warm Drinks
Agitator Motor - Not Running
2
Warm Drinks
Agitator Motor - Not Running
Recirculation Pump Motor -
1
Warm Drinks
Not Running
Recirculation Pump Motor -
2
Warm Drinks
Not Running
Recirculation Pump Motor -
3
Warm Drinks
Not Running
Recirculation Pump Motor -
4
Warm Drinks
Not Running
No Carb
Carbonator Pump Motor -
1
Water
Running
No Carb
Carbonator Pump Motor -
2
Water
Running
No Carb
Carbonator Pump Motor - Not
3
Water
Running
© 2012, IMI Cornelius Inc.

TROUBLESHOOTING

Before looking for problems with the dispensing equipment, first check the following:
1. Is the power connected to the unit?
2. Is the power switch turned on?
3. Is the water connected to the unit?
4. Is the water filter clogged?
5. Are the beverage containers empty?
6. Is the CO
Potential Failure Mode
supply empty?
2
Potential Diagnosis
No Power or Low / High Voltage
Insufficient System Capacity
Low on Charge
Power Switch Off
Low Water Level
Condenser Dirty or Partially
Blocked
Condenser Fan Motor Failure
Compressor internal cut out
Compressor Failure
Main Controller Fail
Controller Failure
Agitator Motor Failure
Recirculation Motor Switch Off
Motion Controller Failure
Pump failure or Blocked
Pump Motor Failure
Blocked
Water inlet pressure switch fail
closed
Out of CO2
- 39 -
Energize6 Service Manual
Check
Check LED - (Green Blinking)
# of Drinks Served/Hr and python
losses. Python and insulation wet?
Refrigerant Pressures. Check ice
bank form. Ice up to the last wind-
ing?
Check Switch Position
Check Water level. Ice bank probe
must be located below water level
Power to / from refrigerant High
Pressure Switch (check reset)
Start compressor and look if the fan
motor starts as well.
Power to compressor? Check volt-
age to each leg (120V to ground)
Check start relay and start capaci-
tor
Check LED - (R&G Blinking)
No Power to agitator motor (power
and signal cable connected?)
Replace the motor
Power Switch
Power to pump motor
Power to pump motor
Replace motor
Filter Screen
Pump falls into the 20min max run
time. Power reset required.
Check LED (Yellow) Check CO2
Supply
Publication Number: 621058457SER