To remove and replace a recirculating pump, perform the procedure in Table 14.
Step
1
Determine which carbonator pump is malfunctioning.
2
Turn off the electrical supply to the unit.
Remove the cover using the procedure in "Removing the Unit Cover" on
3
page 14.
4
Turn off the appropriate recirculating shutoff valves, shown in Figure 15.
- 19 -
Energize6 Service Manual
Figure 12.
Figure 13.
Table 14.
Action
Publication Number: 621058457SER