Replacing The Electronic Ice Probe - Cornelius Energize6 Service Manual

Backroom soda chiller package
Table of Contents

Advertisement

Energize6 Service Manual
R
E
EPLACING THE
Publication Number: 621058457SER
Mounting
Screws
I
P
LECTRONIC
CE
The electronic ice probe is located in the water bath near the center rear of the unit
To remove and replace the electronic ice probe, perform the procedure in Table 20.
Step
1
Turn off the electrical supply to the unit.
2
Remove the cover using the procedure in "Removing the Unit Cover" on page 14
Lower the water level of the water bath by removing the overflow tube from
3
the unit.
Thaw the ice bank. This can be accelerated by pouring warm water into the
4
water bath.
Unplug the connector from the control box, making sure to remove any tie
wraps holding the wiring in place.
TIP: Once all tie wraps have been removed, tie a length of string to the
5
connector before pulling it out of the control board. Then pull the wiring out
of the unit and untie the string. Use the string to fish the new wiring back
through the unit to the control box.
Unsnap the ice probe from the evaporator coil and lift the assembly up
6
and out of the water bath, shown in Figure 30 and Figure 31.
7
Remove the tie wrap from the assembly.
8
Install a new tie wrap to retain the probe to the support clip.
9
Install the assembly back into the water bath.
Replace the overflow tube, if removed, being careful to lubricate the O-
10
rings on the bottom of the tube with water before inserting it into the drain.
Reconnect the connector to the control box and replace the cable ties to
11
keep the wiring away from any hot areas of the unit.
12
Turn on the electrical supply to the unit.
13
When the unit is refilled, replace the unit cover.