EBL/VRM/Trackball Test
Pressing the key and rotating the trackball increases or decreases the number on the screen.
Test Pattern
Pressing the STBY TX key calls up the test pattern composed of circles, squares, and diagonal
lines.

4.5 Notice on Replacing Major Parts

MAGNETRON
NOTE) The magnetron emits a strong magnetic field. For this season, remove a
wrist watch before performing the replacement and use a non-magnetic
screwdriver to dismount the magnetron.
The estimated life of the magnetron is 2000 hours, (including time in stand-by), however actual
life depends on usage.
1. Turn off the power.
2. Dismount the transceiver module.
3. Dismount and replace the magnetron.
4. When a new magnetron is fitted, turn on the power and measure magnetron current. See
Chapter 3 for heater voltage rating, and potentiometer to be adjusted.
5. Allow at least 30 minutes under ST-BY for pre-heating.
6. Transmit on a long range and measure magnetron current. Readjust magnetron current if
necessary.
7. Allow at least 30 minutes under TX for frequency stabilization.
8. Tune the radar : Press [RADAR MENU] [0] [0] [2] [0] [0] [0] [0] and [ENT].

9. Reset
TX Hours
MIC
The MIC can be replaced individually. However, the replacement should be made inside the
room where no radar signal is received. The Tune Initialization must be made after the
replacement.
SPU Board
Settings of the MAIN and INSTALLATION menus are stored onto EEPROM U10 on the SPU
Board.
Remove the U10 on a old board and replace it with one on the new board. The Tune
Initialization must be made after the replacement.



and
On Hours
on the INSTALLATION SETUP menu.
4-8