Light Tower Set Up - Generac Power Systems MAGNUM MTT20IF4 Operating Manual

Combination light tower generator & water trailer
Table of Contents

Advertisement

LIGHT TOWER SET UP

1. For maximum light coverage, locate the unit at ground level or in a spot higher than the area being illuminated
by the lamps.
The mast extends up to 31.5 ft (9.6 m). Make sure the area above the unit is open and
clear of overhead wires and obstructions. Do not set up the unit if high winds or
storms capable of producing lightning are expected in the area.
D
2. Place the unit on firm ground that is relatively flat, then block the wheels to keep it from moving (A). This will
make it easier to level the unit.
3. Turn the tongue jack handle clockwise to raise the trailer tongue off of the towing vehicle (B).
4. Connect a good earthen ground to the grounding stud on the frame of the trailer near the trailer tongue (C).
Note: Refer to local codes for proper grounding requirements.
5. Pull the locking pins on the four leveling jacks (D), rotate them so the jack feet are toward the ground, and insert
the locking pins again to secure the jacks. Adjust all four jacks by turning their handles clockwise until they are
firmly in contact with the ground and the unit is as level as possible.
6. Before raising the mast, it may be necessary to adjust the lamps. The lamps may be adjusted up, down, left or
right by loosening the wing nuts on the trunnion (E) and aiming them in the desired direction. Tighten the hardware
completely and make sure the lamps are connected to the junction box (F).
14
E
C
D
B
WARNING
F
DETAIL C
E
DETAIL D
D
DETAIL E
A
00905

Advertisement

Table of Contents
loading

Table of Contents