Clearances to Combustibles

Minimum clearances to combustible materials in inches (millimeters):
24-1/2"
(622mm)
Min.
12-1/2"
(318mm)
Min.
Figure 3
4-1/2"
(114mm)
Min.
Figure 4
Floor Protection
A noncombustible hearth pad is not required. This stove may be installed
on a combustible surface. Also, the floor beneath the stove must be
stable, level, hard and strong enough to support the stove without a
tipping hazard.
8
Parallel Installation
Back Wall
Corner Installation
90°
10-1/2"
(267mm)
Min.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Alcove dimensions
The minimum width between the alcove side walls is 48" (1219mm).
The minimum height of the alcove is 69" (753mm) and the maximum
depth is 48" (1219mm).
4" (102mm)
69"
(753mm)
Min.
Figure 5 - Alcove Dimensions
Pipe Clearances
All installations using a vertical termination cap must maintain one inch
clearance between the direct-vent pipe and combustibles. For horizontal
runs of pipe, one inch of clearance to combustibles on the sides and
bottom and two inches on the top of the pipe is required. See Page 16
for allowable pipe configurations.
4-1/2"
(114mm)
Min.

INSTALLATION

Install Door Trim Kit
Install door trim kit per instructions provided in kit (ref. form
#775291M).
Figure 6
48"
(1219mm)
Max.
48"
(1219mm)
Min.