Technical Data - Parker D41FE Operation Manual

Pilot operated proportional directional control valve
Table of Contents

Advertisement

Operation Manual

Technical Data

General
Design
Actuation
Size
Mounting Interface
Mounting position
Ambient temperature
MTTF
value
D
Weight
Vibration resistance
Hydraulic
Max. operating pressure
Fluid
Fluid temperature
Viscosity
permitted
recommended
Filtration
Electrical
Duty ratio
Protection class
Supply voltage / ripple
Current consumption max.
Pre-fusing
Input signal
Code K (B) Voltage
Impedance
Code E
Impedance
Code S
Impedance
Input Capacitance typ.
Differential input max.
Code 0
Code 5
Code 7
Enable signal Code 5/7
Diagnostic signal
EMC
Electrical connection
Code 0/7
Code 5
Wiring min.
Code 0/7
Code 5
Wiring lenght max.
D_1FE 5715-688 UK CM 18.01.2019
[°C] -20...+50
[years] 50
[kg]
[g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6
[bar]
[°C] -20...+60 (NBR: -25...+60)
[cSt]/[mm2/s]
[cSt]/[mm2/s]
[%] 100
[V] 22...30, ripple < 5 % eff., surge free
[A] 3.5
[A] 4.0 A medium lag
[V]
[kOhm]
Voltage
[mA]
[Ohm]
Current
[mA]
[Ohm]
[nF] 1
[V] 30 for terminal D and E against PE (terminal G)
[V] 30 for terminal 4 and 5 against PE (terminal W )
[V] 30 for terminal D and E against PE (terminal G)
[V] 5...30, Ri > 8 kOhm
[V] +10...0...-10 / +12.5 V, rated max. 5 mA
[m] 50
Pilot Operated Proportional DC Valve
Series D*1FE
Proportional directional control valve, pilot operated
VCD
®
-actuator
NG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10)
D31
D41
DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
unrestricted
11.3
14.2
10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27
Internal pilot drain P, A, B, X 350; T, Y 35
External pilot drain P, A, B, T, X 350; Y 35
Hydraulic oil acc. DIN 51524 ... 51535, other on request
20...400
30...80
ISO 4406; 18/16/13
IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
+10...0...-10, ripple < 0.01 % eff., surge free, 0...+10 V P–>A (P–>B)
100
+20...0...-20, ripple < 0.01 % eff., surge free, 0...+20 mA P–>B
< 250
4...12...20, ripple < 0.01 % eff., surge free, 12...20 mA P–>A
< 3.6 mA = enable off, > 3.8 mA = enable on acc. NAMUR NE43
< 250
11 for terminal D and E against 0V (terminal B)
11 for terminal 4 and 5 against 0V (terminal 2)
EN 61000-6-2, EN 61000-6-4
6 + PE acc. EN 175201-804
11 + PE acc. EN 175201-804
7 x 1.0 AWG16 overall braid shield
8 x 1.0 AWG16 overall braid shield
6
D81 / D91
D111
23.5
64.5
Parker Hannifin Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

D81feD 1fe seriesD31feD91feD111fe

Table of Contents