Air Bleeding Of Hydraulic System; Filter; Flushing - Parker D41FE Operation Manual

Pilot operated proportional directional control valve
Table of Contents

Advertisement

Operation Manual
Error messages
Malfunctions when using the ProPxD software program will be indicated via appropriate failure messages.
Failure messages and corrective actions:
Failure message
The Com Port is not available! Terminate the other program, or quit the message and select ano-
Unable to open COM port
There is no module/valve
connected or the communica-
tion is disturbed! Please check
also the interface!
Wrong password
Wrong input
Keep the entered parame-
ters?
The chosen module/valve
isn´t the same as the connec-
ted hardware. Attention! Unsa-
ved parameters will be lost.
The chosen hardware isn´t
the same as the connected
module/valve.
Attention! Factory settings
will be changed! Transmit
anyhow?
file name.pxd already exists.
Do you want to replace the
file?

Air Bleeding of Hydraulic System

During initial startup, after an oil change as well as
after the opening of lines or valves the hydraulic
system must be air bleeded.

Filter

The function and lifetime of the valve are strongly
affected by the cleanliness of the fluid.
purity level class of 18/16/13 acc. ISO4406 is
required.
D_1FE 5715-688 UK CM 18.01.2019
Pilot Operated Proportional DC Valve
Series D*1FE
Description/corrective action
ther RS-232 port via the menu "Options > Port". Afterwards recon-
nect the parametrizing cable.
Com port is not available. Quit the message and select another
RS-232 port via the menu "Options > Port". Afterwards reconnect
the parametrizing cable.
No data exchange possible. Either the electronic has been remo-
ved, the port is mismatched, or the connection will be disturbed by
strong electrical fields. Check if the Com port is set for "9600, 8, 1.
none, none" via the menu "Options > Port".
Retype the password, notice the exact spelling (case sensitivity).
An unvalid character or a value outside the permitted range has
been used at parameter entry.
During parameter loading from the electronics memory the preset
parameters from the left hand screen display may be rejected or
maintained.
In principle, parameters dedicated to a type which deviates from
the connected valve may be edited. However, for data transmitting
the correct valve has to be connected. If parameters will be loaded
from a valve which deviates from the selected one, the parame-
ters from the left hand side screen display of the program will be
overwritten.
The wrong valve type has been selected from the database, afte-
rwards the function "send all" has been executed.
Default parameters has been read out from the database instead
from the valve via the function "receive all".
The file name already exists within the indicated directory. Select
another name, another directory or overwrite the existing file with
"OK".

Flushing

It is recommended to flush the pipelines by short
circuiting the pressure and return lines. This prevents
the installation dirt from entering the valve.
18