Installing Three-Phase Ac Output Cables; Oil Fill And Check Location - Hobart 90CU24 Operation And Maintenance Manual

Generator sets
Table of Contents

Advertisement

OM-2084 / Operation and Maintenance Manual
90CU24 / Series 500392 / Generator Set
Lubricating oil capacity with filter
Coolant capacity including radiator
b. Installing Three-phase AC Output Cables
The generator set may be shipped without aircraft cables. The load contactors, to which cables
must be connected, are located on the left side of the unit beneath the engine control panel.
The conductor size recommended for AC output cables is 2/0 AWG. Use No. 12 size for control (E
and F) terminals. Large cables (A, B, C, N) should be equipped with terminals having at least a
3/8-inch diameter mounting hole. Mounting hole in small leads (E and F) should be at least 1/4-inch
diameter.
To install AC output cables proceed as follows:
(1) Open the left front canopy door of the generator set.
(2) Remove plexiglass.
(3) Remove upper panel below door.
(4) Loosen screws on cable clamps located on the side panel beneath the left rear canopy door.
(5) Route cables through cable clamp, and up to the load sides (bottoms) of the load contactors.
Chapter 1-2
Page 2
Oil Level Gauge
Oil Fill

Oil Fill and Check Location

Figure 1
24 Quarts (22.7 liters)
38 Quarts (36 liters)
Figure 2
Capacity
November 27/1997

Advertisement

Table of Contents
loading

Table of Contents