Vhl_Is_Selected - Siemens SIMATIC RF1000 Series Operating Instructions Manual

Simatic ident
Hide thumbs Also See for SIMATIC RF1000 Series:
Table of Contents

Advertisement

Table 6- 29
Byte
0
1
2
3
4
5
6
7
8
9
Table 6- 30
Byte
0
1
2
3
4
5
6
6.3.2.7

vhl_is_selected

Max. reader response time: 3 s
Table 6- 31
Byte
0
1
2
3 ... 4
5
SIMATIC RF1000
Operating Instructions, 02/2019, C79000-G8976-C432-04
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode
0x01
CmdCode
0x04
Parameter length, depending on card type (e.g. 4 bytes)
0x00
0x11
Serial number of the card, depending on card type
0x22
0x33
0x44
0xXX
Optional checksum "BCC8" (when the value "0x1C" is set in byte 0)
Response telegram with errors
Value
Description
0x8C
Without checksum
0x9C
With checksum
0x01
DevCode
0x01
CmdCode
0x01
Parameter length (1 byte)
0x00
0x02
CARD_NOT_SELECTED_ERR
0xXX
Optional checksum "BCC8" (when the value "0x19" is set in byte 0)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode
0x04
CmdCode
0x00
Parameter length (0 bytes)
0xXX
Optional checksum "BCC8" (when the value "0x1C" is set in byte 0)
6.3 Programming via the RS232 interface
Programming
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf1060rSimatic rf1070r

Table of Contents