Adjust The Blower - GE Profile PVM9005FMDS Installation Instructions Manual

Over the range microwave oven
Hide thumbs Also See for Profile PVM9005FMDS:
Table of Contents

Advertisement

Available languages

Available languages

A3
ADJUST BLOWER MOTOR
Remove the screws holding the blower unit and
1
the screws securing the blower plate. Remove
the blower plate from the outer case by sliding it
toward the back of the microwave and pulling up.
Blower Motor Screws
2 Carefully pull out the blower unit. The wires will
extend far enough to allow you to adjust the
blower unit.
14
Installation Instructions
Blower
Plate
Blower
Motor
Screw
A3
ADJUST BLOWER MOTOR (cont.)
Fan Blades
Wires
Roll the blower so that fan blade openings are
3
facing the top of the oven. Place the blower
back into the opening.
Rotate 90°
Note: Make sure the wires remain routed through
the openings in the motor frame. To avoid damage
to the fan motor wiring, insert motor carefully such
that the fan motor wiring does not contact the
microwave power cord bracket.
WARNING
Risk of Electric Shock.
Can cause injury or death. Do not pull or
stretch the blower unit wiring. Make sure the
wires are not pinched.
Slide the blower plate back onto the microwave
4
by placing the side tabs into the slots and
pushing gently until the back tab is seated into
the rear slot. Replace 3 screws.
Side Tab
Side Slot
Back of
Mircrowave
Back of
Mircrowave
Rear Tab
Rear Slot
49-40755 Rev.1