Specifications

Parameter
Pipe Threading Capacity
Die Head Holding
LH Threads
Support Arm
Adapter
Motor Type
Watts
Voltage/Phase Available
Amps
Operating Speed (RPM)
Controls
Gear Head
Length
Width
Height
Weight
Sound Pressure (L
Sound Power (L
WA
Vibration*
* Sound and Vibration measurements are measured in accordance with a standardized test per Standard EN 62481-1.
- Vibration levels may be used for comparison with other tools and for preliminary assessment of exposure.
- Sound and vibration emissions may vary due to your location and specific use of these tools.
- Daily exposure levels for sound and vibration need to be evaluated for each application and appropriate safety measures taken when needed. Evaluation of exposure
levels should consider the time a tool is switched off and not in use. This may significantly reduce the exposure level over the total working period.
999-999-476.10_REV. D
Find Quality Products Online at:
Warning
F/R
Label (120V)
Brush
Switch
Cap
Serial Plate
Brush Cap
Motor
Fan Housing
Gear Housing
600-I Power Drive
1
/
to 1
1
/
inch
8
4
(3 to 32 mm)
Ring Spring
Yes
No. 602, No. 601
Not Required.
Universal Motor, Single Phase
1270 (120V), 1020 (220-240V)
120V/1PH, 220-240V/1PH
12A (120V), 5A (220-240V)
36 (120V), 32 (220-240V)
Forward/Reverse Slide Switch
ON/OFF two-step momentary contact switch
Die Cast Aluminum Permanently Greased
20 inch (508 mm)
3.75 inch (95 mm)
7.5 inch (191 mm)
12.65 lbs (5.7 kg)
)*
83 dB(A), K=3
PA
)*
94 dB(A), K=3
< 2.5 m/s
2
, K=1.5
GlobalTestSupply
www.
600-I Power Drive and 690-I Power Drive machine serial
number plate is located on the bottom of motor housing.
Handle
The last 4 digits of the serial number indicate the month
and year of the manufacture (MMYY).
Cord
ON/OFF
Switch
Figure 4 – Machine Serial Number

Standard Equipment

The Model 600-I/690-I Power Drives come with the fol-
lowing items:
• Power Drive
• 690-I Adapter (690-I only)
• Operator's Manual
NOTI E
lation, joining and forming methods is the responsibility of
the system designer and/or installer. Selection of improp-
er materials and methods could cause system failure.
Stainless steel and other corrosion resistant materials
can be contaminated during installation, joining and form-
600-I/690-I Power Drives
Selection of appropriate materials and instal-
690-I Power Drive
1
/
to 2 inch
8
(3 to 50 mm)
Retaining Mechanism (1
1
/
2
Ring Spring (
1
/
– 1
1
/
inch)
8
4
Yes
No. 692, No. 691
Used with
1
/
" through 1
1
/
" Die Heads.
8
4
Universal Motor, Single Phase
1270 (120V), 1020 (220-240V)
120V/1PH, 220-240V/1PH
12A (120V), 5A (220-240V)
36 (120V), 32 (220-240V)
Forward/Reverse Slide Switch
ON/OFF two-step momentary contact switch
Die Cast Aluminum Permanently Greased
24.13 inch (613 mm)
4.75 inch (121 mm)
8 inch (203 mm)
21.15 lbs (9.6 kg)
83 dB(A), K=3
94 dB(A), K=3
< 2.5 m/s
2
, K=1.5