Lincoln Electric OPTIMARC CV/CC 500 Operator's Manual page 6

Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS –
Standard Voltage / Phase / Frequency
Max Input Power at Rated Output ( SMAW )
Welding Mode
GMAW
SMAW ( STICK )
GTAW ( TIG )
Welding Mode
GMAW
SMAW ( STICK )
GTAW ( TIG )
®
OPTIMARC
CV/CC500
®
OPTIMARC
CV/CC500
Operating Temperature Range
Storage Temperature Range
For any maintenance or repair operation it is recommended to contact the nearest technical service center or directly
consult machine division of the Shanghai Lincoln Electric. Maintenance or repairs performed by unauthorized service
center or personnel will void the manufacturer's warranty.
INSTALLATION
INPUT – THREE PHASE ONLY
RATED OUTPUT – DC ONLY
Duty Cycle
60%
100%
60%
100%
60%
100%
OUTPUT RANGE
Welding Current Range
50A ~ 500A
15A ~ 500A
5A ~ 500A
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input Voltage/
Maximum
Frequency
Input
(Hz)
Ampere
380~415 V/
50Hz or 60Hz
51A
PHYSICAL DIMENSIONS
Height
540mm
TEMPERATURE RANGE
OPTIMARC
®
OPTIMARC
CV/CC500
380V ~ 415V (±10%) / 3 / 50 or 60 Hz
23 kVA @ 60% Duty Cycle
Amperes
500A
390A
500A
390A
500A
390A
Open Circuit Voltage
60V
60V
60V
Maximum
60° C Copper
Effective
Wire in
Supply
Conduct
Current
Sizes
40A
12mm
Width
340mm
®
CV/CC500
Volts at Rated Amperes
39V
33.5V
40V
35.6V
30V
25.6V
Welding Voltage Range
16 V ~ 39V
20.6 V ~ 40V
10.2 V ~ 30V
Fuse or
Breaker Size
(Super Lag)
2
60A
Depth
Weight
800mm
-10° C ~ +40° C
-25° C ~ +55° C
A-1
Grounding
Conductor
Size
2
10mm
47Kg
Rev. 03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents