Information
Base Station System
A30808-X3247-L14-2-7618
Redundancy:
–
SW Support of Core Redundancy
–
SW Support of BCCH Redundancy
–
AC/DC n+1 redundancy. (n+1) AC/DC Converters work in load sharing, but n AC/DC
are able to supply the whole BS-240/241 including Service Racks/Shelters
Abis interface:
–
Enhanced Full-Rate TCH
–
Full-Rate and Half-Rate TCH
–
AMR TCH
–
Submultiplexing 4 x 16 kbit/s onto one 64 kbit/s timeslot for handling Full-Rate TCH
on Um interface
–
Handling of 4x(2x8) kbit/s onto one 64 kbit/s timeslot for half-rate TCH on Um inter-
face
–
Drop and insert feature on 2 Mbit/s (E1) and 1.5 Mbit/s (T1) links is available on a
16 kbit/s and a 64 kbit/s basis
–
Star, loop and multidrop chain connections
–
Cross connect function
–
Change of PCM line configuration from star to multidrop or loop and vice versa is
possible without any interruption of service
–
Multiple Abis LAPD links; load sharing and LAPD fault recovery
–
External clock synchronisation
–
Over-Voltage Protection with OVPT
Abis link media:
–
Wire
–
Fiber optic
–
Micro-Wave
Fault procedures:
–
Automatic Recovery procedure of faulty objects in BTS
–
Online RF Loopback
Technical Description (TED:BSS)
BS-240/241
11