Chapter 6 : Technical Specifications
Model
Capacity
Voltage Range
Frequency Range
Connection
Phase
Nominal voltage
Voltage Regulation
Frequency Range
(Batt. Mode)
Connection
Overload
Current Crest Ratio
Harmonic Distortion
Waveform
(Batt. Mode)
Normal Mode
Buck & Boost Mode
MX-1.1K
1100VA / 990W
Input
200V: 150-234V / 208V: 156-243V / 220V: 162-268V
/ 230V: 170-280V / 240V: 177-290V
50/60 Hz (auto sensing)
IEC C14
Single phase with ground
Output
200V / 208V / 220V / 230V / 240V
±1.5% (Batt. Mode)
50 Hz or 60 Hz ± 1 Hz
IEC C13 (4+4)
103% ~ 120%: 5 minutes (1 minutes @battery mode),
120% ~ 150%: 10 seconds,
>150%: UPS shutdown immediately
≤ 2%(linear load), ≤ 5% (non-linear load)
Efficiency
98%
95.5%
3 4
Chapter 6
Technical Specifications
MX-2K
2000 VA / 1800 W
IEC C20
3:1
Pure Sinewave
96.5%
MX-3K
3000VA / 2700W
IEC C13 (4+4)
IEC C19 (1)
98.5%