Installing The System; Card And Battery - Emerson Rosemount 375 Getting Started

Field communicator w/ foundation fieldbus & hart
Hide thumbs Also See for Rosemount 375:
Table of Contents

Advertisement

Installing the System Card and battery
Figure 3. Back side of the 375 Field Communicator
I
NSTALLING THE
1. Place the 375 Field Communicator face down on a level, secure surface.
2. Lock the stand into the hanger position. To pivot past the stand position, squeeze
the stand together near the hinge, see Figure 3.
3. With the battery removed, place the System Card (labeled System Card), with the
card contacts facing up, on the System Card guide ribs located directly below the
battery connector. Slide the System Card forward into the System Socket until it is
firmly in place.
The System Card must not be inserted into the Expansion Port. Failure to comply
can cause hardware damage and will void the IS approval and the warranty.
4. With the 375 Field Communicator still face down, ensure the tops of the two battery
retaining screws are flush with the top of the communicator. Install the battery by
aligning the sides of the battery and the communicator, and carefully sliding the
battery forward until it is secure.
CAUTION
If the battery and 375 Field Communicator are not properly aligned, the connector pins
can be damaged.
5. Carefully hand tighten the two battery retaining screws to secure the battery. (Do
not over tighten, 0.5Nm maximum torque load.) The tops of the screws should be
close to flush with the stand groove.
Main unit label
Battery
retaining
screws
Battery
S
C
YSTEM
ARD AND BATTERY
WARNING
System Card
7
Stand
assembly
IS label
(KL Option)